Erhardt-leimer Do 3001 Manual Free
Remove the web entirely from the sensor's viewing window. Press the "Calibrate Clear" or "Sensor Zero" button on the interface.
Invert the control direction setting via the menu interface. Dust/debris accumulation; Broken cable connection.
The DO 3001 is part of the E+L digital web guider family, commonly paired with (like ZC 4002 or integrated controllers). It serves as the primary interface for operators, featuring an intuitive touch-panel interface for real-time adjustments and monitoring of the web path.
The DO 3001 must learn the material edge or line. The manual calls this "Teach-In". Procedure: Erhardt-leimer Do 3001 Manual
Ensure the bracketry is entirely free from machine vibration. Structural vibration mimics web weave, causing the guiding system to over-correct. Electrical Connections The DO 3001 uses a standard industrial round M12 connector. Power and data travel through a unified CAN bus cable.
The technical specifications of the Erhardt-Leimer Do 3001 are:
Maintain the exact distance between the sensor nose and the material web as specified on your unit’s dimension sheet (typically 10mm to 20mm for optical variants). Remove the web entirely from the sensor's viewing window
: Operators use the unit to set specific guiding setpoints, sensor sensitivity, and actuator speeds to optimize the process. Operational Workflow According to standard operating manuals for E+L command stations
Trigger the "Covered / Material" calibration option on the controller.
24 V DC (typically sourced from the parent E+L controller) Dust/debris accumulation; Broken cable connection
Use a soft, lint-free microfiber cloth moistened with isopropyl alcohol.
Secure the device using the provided rear mounting brackets and screws. Do not overtighten. Electrical Connections